Energy generation and electrical engineering

Modeling of mechanical loss in electrically driven centrifugal pump functioning

Authors

P. M. Nykolyn
Ivano-Frankivsk National Technical University of Oil and Gas ROR

Keywords

electrically driven centrifugal pump energy efficiency mechanical resistance power

Abstract

Mathematical model of mechanical loss in electrically driven centrifugal pump functioning is built; graphic dependences of work efficiency are defined for the centrifugal pump НМ- 7000-210. Importance of variable mechanical output-input ratio account is substantiated for the complete estimation of efficiency of work of the pump.
287 83

How to Cite

[1]
“Modeling of mechanical loss in electrically driven centrifugal pump functioning”, Вісник ВПІ, no. 2, pp. 136–138, Nov. 2010, Accessed: Oct. 30, 2026. Available: https://visnyk.vntu.edu.ua/index.php/visnyk/article/view/1216

Author Biography

P. M. Nykolyn, Ivano-Frankivsk National Technical University of Oil and Gas
аспірант кафедри електропостачання та електрообладнання