THE EFFICIENCY OF RECUPERATION THE ELECTRIC POWER IN ELECTRIC TRANSPORT SYS-TEM WITH INVERTER DC TRACTION SUBSTATIONS
Keywords
Abstract
There have been presented the results of experimental study of the performance of inverter substations of electric traction system of direct current in the mode of recuperation. There has been found that inversion aimed to excess energy recovery of trains does not provide optimal distribution and proper mode voltage in the traction network, which requires the development of appropriate organizational and technical measures for the organization of train movement and traction power supply. Quality indicators of energy recovery at the connectors 35 kV traction substations are within the scope of maximum permissible values established by the standard.