Starting Modes of Asynchronous Electric Drive of Superresonance Vibration Machine
Keywords
Abstract
The calculation of the power of the drive induction motors of an unregulated electric drive for vibration machines with unbalanced exciters operating in the superresonance zone has been proposed in the paper. The power calculation is oriented to the starting mode of the electric drive operation for the previously known design parameters of the vibration machine. The results of the calculation of the nominal moment and power of the 4A series induction motors for an industrial vibration platform used for compacting concrete mixtures in a mold have been given.