Energy generation and electrical engineering
THE CALCULATION OF HEAT EXCHANGE IN DUCTINGS WITH RAY ACCEPTING INSERTIONS
Keywords
теплообмін
рекуператор
променесприймальна вставка
турбулентний режим
коефіцієнт тепловіддачі
Abstract
There has been conducted the research in relation to the influence of geometry of different insertions on the coefficient of heat emission from the wall of metallic high temperature recuperator. The conclusion is that ray accepting insertions with the number of sectors from 2 to 6 are real for application in modern recuperators. There also has been developed the criterion dependence that is universal for this mode.
How to Cite
[1]
“THE CALCULATION OF HEAT EXCHANGE IN DUCTINGS WITH RAY ACCEPTING INSERTIONS”, Вісник ВПІ, no. 4, pp. 52–56, Sep. 2015, Accessed: Oct. 06, 2026. Available: https://visnyk.vntu.edu.ua/index.php/visnyk/article/view/766